Ia lube oil motor motor
ia lube oil motor motor fbkw8 4 pole 460 v 3.0 a 1.5 kw 1720 rpm 60 hz frame 90l
Detail Toshiba Three Phase Induction Motor Type : IK, IKK, TIKK DCKK8, DCK21, DBKK8, DBK21, EBKK8, FCKK8, FBKK8, FCKA21, FBKA21, FBK21, FCK21
1. The motor is generally installed in a clean and dry place indoors. The surrounding air must be well ventilated. The maximum ambient air temperature does not exceed 40 °C, the lowest temperature is not lower than -15 °C, and strong heat radiation should be prevented.
2. The motor control appliance should have phase loss protection and overload thermal protection device. The YA series increased safety motor should select the appropriate overload thermal protection device according to the nameplate tE time and starting current ratio IA/IN.
3. Connect the power cable according to the wiring diagram. The terminal should be fastened. The motor with the cable and wire can be connected directly to the power cable. The joint should be insulated and sealed.
4. When the power line, phase sequence and electric thick lug mark are connected, the motor rotates clockwise from the shaft end. When you need to change the steering, change the position of the two power cords.
5. YD series and other variable-speed multi-speed asynchronous motors use the method of changing the lead-out line to control the change of the speed. In order to ensure the reliability of multi-speed motor operation, it should be noted when designing and operating the control device, when switching to low speed at high speed. The neutral point of the 2Y wiring must be disconnected while the power is off, so as to avoid short-circuiting the power supply when the low-speed winding is turned on. In the process of switching to low speed at high speed, the power supply of the low speed winding must be turned on after the motor is stopped to reduce the impact on the motor and the load. Speed switching should pay attention to the steering of the motor.
6. The ia lube oil motor motor fbkw8 4 pole 460 v 3.0 a 1.5 kw 1720 rpm 60 hz frame 90l motor can be equipped with a coupling, the gear, the belt and the load are mechanically coupled. The 4-pole motor above 4kw and the 4-pole motor above 30kw should not be driven by a belt. The second shaft extension of the double-shaft extension can only be used with a coupling. transmission. The coupling of the coupling, the pulley shaft hole and the motor shaft should be suitable. It is strictly forbidden to strike with a heavy hammer during installation. When using the coupling drive, the center line of the motor shaft and the center line of the load mechanical shaft should coincide.
The coupling retains a 1 to 3 mm clearance in the axial direction. When the belt is used to convey the chamber movement, the center line of the motor shaft should be parallel to the center line of the load mechanical shaft, and the center line of the belt and the center line of the shaft are perpendicular to each other.
TOSHIBA Three Phase Induction Motor Type : IK, IKK, TIKK DCKK8 DCK21 DBKK8 DBK21 EBKK8 FCKK8 FBKK8 FCKA21 FBKA21 FBK21 FCK21 TO SHIBA - Induction Motor IK-FBKK8 0.75KW 380V / 50HZ 4P IK-FBKW8 0.75KW 380V / 50HZ 4P S / N: 50108351 IK-FBBKK8 IK-FBKA21-4P-1.5KW IK-FBKA21-4P-7.5KW IK-FCKL 0.4KW 200V 50HZ 4P IKK-FBKA21-132M-7.5KW-4 S / N: 60260680 OS: 6306zzLS: 6308ZZ IKK-FBKA21-4P-11KW TIKE RCAIN 10000V 4200KW 315A 50HZ series: 20 Level 296RPM F SERIAL NO: D069250EM TIKK, FBKAW21, 160L, 15KW, 4P TIKK-FBK21 37KW 4P 400V totally-enclosed fan 1460rpm IK-FBKA21-4P-2.2KW ( Cap) for IK-FCKLA21 6P 3.7KW 380V S / N: 92965708 FCKLKBS8-4P-0.2KW FCKLKBS8-4P-0.75KW G3F32N450-CTB020WA IK FCKL21 0.4KW 4Ppoles 3phase 380V 50HZ serial no: 34061301 IKC-ECKLK8 2.2KW 4P IP44 380V / 50HZ S / N: 42577087 IK-DBKK8 0.75KW 200V 50HZ 4P IK-DBKK8 1.5KW POL 380V / 50HZ S / N: 42334458 IK-DBKK8 22KW 200V 50HZ 4P S / N: 12498292 IK-DBKK8-100L 2.2KW 4P 200V / 50HZ IK-DBKK8-4P-2.2KW 200V IK-DCKLK8 0.55KW 4P 380V 50HZ IK-DCKLK8 0.75KW 220V IK-DCKLK8 1.5KW 4P 200V 50HZ IK-FBK21 11KW 4P 380V / 50HZ IK-FBK21 15KW 4P 380V / 50HZ IK-FBK21 3.7KW 4P 380V / 50HZ IK - FBK21 3.7KW 4P 380V / 50HZ IK-FBK21 4P 11KW 380V / 50HZ IK-FBK21 4P 15KW 380V / 50HZ IK-FBK8 1.5KW 200V 50HZ 4P IK-FBK8 4P 2.8KW 380V 50HZ IK-FBK8 0.2KW 4P Frame size: 63 220 / 380V / 50HZ IK-FBK8 now type: IK-FBKA21 2.2KW 380V 50HZ 4P IK-FBK8 new models: IK-FBKA21 3.7KW 380V 50HZ 4P IK-FBKA21 1.5KW 4P 380V / 50HZ IK-FBKA21 3.7KW 4P 380V / 50HZ IK-FBKA21 0.75KW 4P 380V / 50HZ IK-FBKA21 1.5KW 4P 380V / 50HZ IK-FBKA21 1.5KW 6P 100L IP44 380V / 50HZ S / N: 40186589 IKH-FBK8 1.5KW 6P 380V / 50HZ IK-FBKA21 2.2KW 4P 380V / 50HZ IK-FBKA21 3.7KW 4P 380V / 50HZ IK-FBKA21 3.7KW 200V
1. In the case of correct use and storage by the user in accordance with the provisions of the maintenance and repair instructions, the motor may be damaged or not working due to manufacturing quality problems within one year from the date of purchase or within one year of the company's production date. Our company is responsible for repairing, replacing, and returning.
2, due to user-induced motor failure, our company can provide motor repair service, and charge a certain fee according to the regulations, generally including the following situation: the motor due to the voltage exceeds the rated voltage ± 5% or overload operation, resulting in the burning of the motor; The motor is faulty due to the failure of the three-phase power supply line, causing the one or two phase windings of the stator winding of the motor to burn out; equipment accidents caused by installation, use and maintenance that are not required by the maintenance and repair instructions; motors that are disassembled and repaired by the user.